Physicochemistry of Carbon Materials
Research Group

Equipment

cccccccccccccccccccccccccccccccccccccccccc

Equipment

cccccccccccccccccccccccccccccccccccccccccc

cccccccccccccc









          Tian-Calvet          
          microcalorimeter          
          (volumetric adsorption          
          apparatus with          
          Baratron transducers          
          for pressure measurements)          

          Calvet microcalorimeter          
          (enthalpy of immersion          
          measurements)          

          Flow calorimeter          
          (enthalpy of drug          
          adsorption/delivery          
          measurements)          

          Anareal chamber for          
          underpressure processes          
          (sterile conditions)          

          UV-Vis Spectophotometer          
          JASCO V-550          
          (concentration of drug in          
          solution measurements)          

          UV-Vis Spectrophotometer          
          JASCO V-650          
          (concentration of drug in          
          solution measurements)          

          Qualitative and quantitative          
          adsorption system from          
          gaseous phase - IR          
          measurement equipment          

          Temperature programmed          
          apparatus to experimental sets,          
          for example TPD, TPO, TPR etc.          

          Controlled drug          
          adsorption/delivery system          
          (in accordance Polish          
          Pharmacopeia regulations)          

          ASAP 2010 Micromeritics          
          (adsorption, BET surface,          
          porosity determination)          

          GEMINI VI Micromeritics          
          (adsorption, BET surface,          
          porosity determination)          

          Computer cluster          
          (simulations, quantum          
          calculations)          
          (2009, 2008, 2007, and 2006,          
          respectively)          
          - under construction          

          Gas Chromatograph GCHF 18.3          
          coupled with microreactor          

          Gas Chromatograph CHROM 4          
          with built-in microreactor          

     Moreover, in our studies we used
the following thechniques:     

CCCCCCCC

    
  • EA (Elemental Analysis)     
  • Thermogravimetry     
  • SAXS (Small-angle X-ray Scattering)     
  • XRD (X-ray Diffraction)     
  • XPS (X-ray Photoelectron Spectroscopy)     
  • FTIR (Fourier Transform Infrared Spectroscopy)     
  • HRTEM (High-Resolution Transmission Electron Microscopy)     
  • TPD (Temperature Programmed Desorption)     
  • AFM (Atomic Force Microscopy)     
  • NMR (Nuclear Magnetic Resonance)